Single Core | |||||||||||||||
Unscreened Category | |||||||||||||||
Rubber Type | |||||||||||||||
Voltage |
Cable Type |
Construction |
Number of Cores |
Cross Sectional |
Design Standard |
Fire Standard |
|||||||||
300/500V | Single Core, unsheathed | CU/EPR-CSP dual insulation | 1C | 1.0mm sq-16 mm sq, Class 5 Stranding | N/A | N/A | |||||||||
|
Single Core, unsheathed | CU/EPR-CSP dual insulation | 1C | 1.0mm sq-400 mm sq, Class 5 Stranding | N/A | N/A | |||||||||
1800/3000V | Single Core, unsheathed | CU/EPR-CSP dual insulation | 1C | 1.0mm sq-400 mm sq, Class 5 Stranding | N/A | N/A | |||||||||
650/750V | Single Core, unsheathed | CU/EPR | 1C | 150mm sq-1000 mm sq, Class 2 Stranding | RT/E/S/21101 | N/A | |||||||||
LSOH Type | Standing |
||||||||||||||
300/500V | Single Core, unsheathed | CU/EI 107 EPR | 1C | 10 AWG-20AWG 19/37 Standing 0.5mm sq- 4 mm sq, Class 5 Stranding |
EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
300/500V | Single Core, with jacket | CU/EI107 EPR/EM 104 EV A | 1C | 1.0mm sq-400 mm sq, Class 5 Stranding | TM1 -05 | BS 6853A/B/II, NF F 16 101 | |||||||||
600/1000V | Single Core, unsheathed | CU/EI 107 EPR | 1C | 0.5mm sq- 400 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
600/1000V | Single Core, with jacket | CU/EI107 EPR/EM 104 EV A | 1C | 1.0mm sq-400 mm sq, Class 5 Stranding | TM1 -05 | BS 6853A/B/II, NF F 16 101 | |||||||||
600/1000V | Single Core, unsheathed fire resistant | CU/MICA/EI107 EVA | 1C | 1.5mm sq- 400 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4, EN 50200 (15MIN) | |||||||||
600/1000V | Single Core, with jacket fire resistant | CU/MICA/EI107 EPR/EM 104 EVA | 1C | 1.5mm sq- 16 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4, EN 50200 (15MIN) | |||||||||
1800/3000V | Single Core, unsheathed | CU/EI 107 EPR | 1C | 25mm sq- 400 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
1800/3000V | Single Core, with jacket | CU/EI 110 EPR/EI 104 EPR | 1C | 25mm sq- 400 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
3600/6000V | Single Core, unsheathed | CU/EI 104 EPR/EM 104 EVA | 1C | 1.0mm sq-400 mm sq, Class 5 Stranding | EN 50264-3-1 | BS 6853A/B/II, NEN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4F F 16 101 | |||||||||
3600/6000V | Single Core, with jacket | CU/EI 104 EPR/EM 104 EVA | 1C | 1.0mm sq-400 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
Screened Category | |||||||||||||||
LSOH Type | |||||||||||||||
300/500V | Single Core screened, with jacket | CU/EI 110 EPR/CUTO/EM 104 EVA | 1C | 2.5mm sq- 25 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
600/1000V | Single Core screened, with jacket | CU/EI 110 EPR/CUTO/EM 104 EVA | 1C | 2.5mm sq- 25 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
1800/3000V | Single Core screened, with jacket | CU/EI 110 EPR/CUTO/EM 104 EVA | 1C | 1.0mm sq-300 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
3600/6000V | Single Core screened, with jacket | CU/EI 104 EPR/CUTO/EM 104 EVA | 1C | 1.0mm sq-400 mm sq, Class 5 Stranding | EN 50264-1,2,3 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
Multicore | |||||||||||||||
Unscreened Category | |||||||||||||||
Rubber Type | |||||||||||||||
300/500V | Multicore, with jacket | CU/EPR/PCP | 1,2,3 Prs | 1.0mm sq-4.0mm sq | N/A | N/A | |||||||||
300/500V | Multipair, with jacket | CU/EPR/PCP | 12-42C | 1.0mm sq-4.0mm sq | N/A | N/A | |||||||||
LSOH Type | |||||||||||||||
300/500V | Multicore, with jacket | CU/EI 110 EPR/EM 104 EVA | 1-21C | 0.75mm sq - 6 mm sq, Class 5 Stranding | EN 50264-3-2 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
600/1000V | Multicore, with jacket | CU/EI 110 EPR/EM 104 EVA | 1-21C | 0.75mm sq - 6 mm sq, Class 5 Stranding | EN 50264-3-2 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4 | |||||||||
600/1000V | Multicore, with jacket fire resistant | CU/MICA/EI107 EVA | 1-21C | 0.75mm sq- 6 mm sq, Class 5 Stranding | EN 50264-3-1 | EN 50267-2-1/2, EN50305, EN 50305, EN 50268-2, BS6853, DIN 5510 P1, HAZARD LEVEL 1-4, EN 50200 (15MIN) | |||||||||
1800/3000V | Multicore, with jacket | CU/EI 110 EPR/EM 104 EVA | 2-37 C | 1.5mm sq-2.5 mm sq, Class 5 Stranding | EN 50264-3-1 | BS 6853A/B/II, NF F 16 101 | |||||||||
Databus RS 485 Cable | |||||||||||||||
300/500V | Multipair, with jacket screened | CU/XL FOAM PE/ALTO/CUTO/EM 104 EVA | 1-4 Pr | 0.22-1mm sq, Class 5 stranding | EN 50264, DIN 5510 | IEC 332-3C IEC 754 IEC1034 |
|||||||||
300/500V | Multipair, with jacket screened | CU/XL FOAM PE/CUTO/EM 104 EVA | 1-4 Pr | 0.22-1mm sq, Class 5 stranding | EN 50264, DIN 5510 | BS 6853 NF F 16-101 FO |
|||||||||
RSE/STD/024 Part 6 Rolling Stock Cable | |||||||||||||||
600/1000V | Single Core, unsheathed | CU/EM 104 EVA | 1C | 0.5mm sq - 4mmsq, 19/37 strand | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
600/1000V | Single Core, unsheathed | CU/EM 104 EVA | 1C | 0.75mm sq - 300 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
600/1000V | Single Core, unsheathed | CU/EM 104 EVA | 1C | 50mm sq - 185 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
300/500V | Single Core, unsheathed | CU/EM 104 EVA | 1C | 0.5mm sq - 4 mmsq, 19/37 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
300/500V | Single Core, unsheathed | CU/EM 104 EVA | 1C | 0.5mm sq - 10 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
600/1000V | Multicore, with jacket | CU/EI 104 EPR/EM 104 EVA | 10/20C | 2.5mm sq -4mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
300/500V | Multicore, with jacket | CU/EI 104 EPR/EM 104 EVA | 12/42C | 1.0mm sq-1.5 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
300/500V | Multipair, with jacket screened | CU/EI 104 EPR/CUTO/EM 104 EVA | 1,2,3 Prs | 0.5mm sq-1.0 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
300/500V | Multipair, with jacket screened | CU/EI 104 EPR/CUTO/EM 104 EVA | 1,2,3,4 Prs | 0.5mm sq-1.0 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
600/1000V | Singlepair, with jacket screened | CU/EI 104 EPR/CUTO/EM 104 EVA | 1 Prs | 1.0 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
300/500V | Single Core, unsheathed | CU/EM 104 EVA | 1C | 1.0mm sq-6.0 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 | |||||||||
300/500V | Multicore, with jacket | CU/EI 104 EPR/EM 104 EVA | 12/42C | 1.0mm sq-1.5 mmsq, Class 5 stranding | RSE/STD/024 Part 6 | IEC 332-3C IEC 754 IEC1034 |